Filling the compressed air cylinders
WARNING
Danger of injuries due to the use of non-approved or damaged filling equip-
ment and compressed air cylinders!
Unsuitable or damaged material may burst or tear under pressure.
Use only approved filling devices and compressed air cylinders.
Ensure that filling equipment and compressed air cylinders are in a flawless
condition.
Ensure that the compressed air cylinder to be connected for the filling pres-
sure are approved; refer to the stamp on the shoulder of the cylinder.
NOTICE
The final pressure safety valve is not designed for continuous operation.
Shut off the unit after reaching the filling pressure.
For units with automatic switch-off, check if the unit shuts off when the filling
pressure has been reached.
Start safety valve only within the periodic maintenance.
Compressed air cylinders with an international filling connection can be connected
with the international bracket filler connection (order number 79375).
Fig. 18 Filling the compressed air cylinders
1 Connect compressed air cylinder 3 Open cylinder cock 5 Close filling cock
2 Open filling cock 4 Close cylinder cock
1.
Connect the compressed air cylinder to the cylinder connection.
2.
Open filling cock.