Parameter description
Parameter manual b maXX
®
1000
Document no. 5.07004.03 Baumüller Nürnberg GmbH
100
of 208
4.3
P1140
The parameter are used to set the analog input reference values. The min and max fre-
quencies are based on ZP0033 (during open-loop control) as shown in the following.
Figure 48: Analog input reference values 3
Example see ZFigure 44 and ZFigure 45on page 95.
P1141
The parameter are used to set the analog input reference values and is based on percent-
age of ZP0033). For further information see ZP1139 and ZFigure 48on page 100.
P1142
For further information see ZP1139 and ZFigure 48on page 100.
P1143
For further information see ZP1139 and ZFigure 48on page 100.
P1140
Minimale AVI3 Spannung 0.0 to 10.0 V
EE Minimum AVI3 voltage 0.1 V
STOP BM_u_MinimumAVI3Voltage 10:1
P1141
Minimale AVI3 Frequenz 0.0 to 100.0 %
EE Minimum AVI3 frequency 0.0 %
STOP BM_u_MinimumAVI3Frequency 10:1
P1142
Maximale AVI3 Spannung 0.0 to 10.0 V
EE Maximum AVI3 voltage 0.1 V
STOP BM_u_MaximumAVI3Voltage 10:1
P1143
Maximale AVI3 Frequenz 0.0 to 100.0 %
EE Maximum AVI3 frequency 0.0 %
STOP BM_u_MaximumAVI3Frequency 10:1