4.3
P1364
This parameter defines an upper bound or limit for the integral gain (I) and therefore limits
the master frequency.
The formula is:
Integral upper bound = maximum output frequency ZP0033– x ZP1364–.
This parameter can limit the maximum output frequency.
Complete PID diagram see ZP1369–.
P1365
To avoid amplification of measurement noise in the controller output, a derivative digital
filter is inserted. This filter helps to dampen oscillations.
Complete PID diagram see ZP1369–.
P1366
This parameter defines the percentage of output frequency limit during the PID control.
The formula is:
Output frequency limit = maximum output frequency ZP0033– x ZP1366–.
This parameter will limit the maximum output frequency. An overall limit for the output fre-
quency can be set in ZP0040–.
Complete PID diagram see ZP1369–.
P1364
Obere Grenze Integralverstärkung 0 to 100 %
EE Upper bound for integral control 100 %
STOP BM_u_UpperBoundIntegralControl 1:1 -
P1365
Hauptfilter Verzögerungszeit 0.0 to 2.5 s
EE Primary delay filter time 0.0 s
STOP BM_u_PrimaryDelayFilterTime 10:1 -
P1366
Ausgangsfrequenz Grenze 0 to 110 %
EE Output frequency limit 100 %
STOP BM_u_OutputFrequencyLimit 1:1 -