Parameter description
Application handbook Servo pump function V1 for BM5000
Document No.: 5.17002.02 Baumüller Nürnberg GmbH
68
of 76
6.3
177.194 Actuating variable 4
DS-support DINT 0 to 32767
Control difference of the adaption point 1.
Scaling: 32767 Inc = ZP177.6– or ZP177.7–
177.195 P-gain 0
DS-support DINT 0 to 65535
P-gain 0 (control difference < actuating variable 1).
Scaling: 100:1
177.196 P-gain 1
DS-support DINT 0 to 65535
P-gain 1 (control difference > Actuating variable 1 AND Control difference < Actuating
variable 2)
Scaling: 100:1
177.197 P-gain 2
DS-support DINT 0 to 65535
P-gain 2 (Control difference >Actuating variable 2 AND Control difference <Actuating
variable 3).
Scaling: 100:1
177.198 P-gain 3
DS-support DINT 0 to 65535
P-gain 3 (Control difference > Actuating variable 3 AND Control difference < Actuating
variable 4).
Scaling: 100:1
177.199 P-gain 4
DS-support DINT 0 to 65535
P-gain 4 (Control difference > Actuating variable 4).
Scaling: 100:1