Page #107 background imageLoading...
Page #107 background image
107
Sun protection
Drives
Setting the limit positions using the programming unit
1. Programming the limit
positions
Connect the wires of the tubular
drive to those of the same colour in
the programming unit.
Run the shading solution to the
desired position and press the
programming button until the drive
clicks once.
Then run the shading solution in the
retract direction until it stops auto-
matically at the upper limit.
2. Deleting the limit positions
using the programming unit
- Press and hold the programming
button
- Press and hold the button
-
Release the programming button
- Press the programming button
again until the drive clicks twice.
If the drive is situated between the
limit positions, both limit positions
are deleted. If the drive is situated
in one of the limit positions, only this
position will be deleted.
1x click