Setting the limit positions via Autoinstall
C18 drives
1. Programming the Retract
limit position
Run the shading solution towards
the stop until the drive stops auto-
matically.
2. Programming the Extend
limit position
Travel in the Extend direction and
keep the travel button pressed, until
the drive moves past the Extend limit
position
, then moves upwards
and then downwards
, in order to
finally stop in the Extend limit posi-
tion and to confirm the programming
procedure with a click .