On Control Console:
kM,M~::r
~PUSH RICH
OF~O ~+
HI ALTERNATE AIR
AIR COND PULL AND RELEASE
*Located on copilot's subpanel in airplanes with 28-volt
electrical system
On Lower Edge of
Floating Panel:
f - AIR CON0. - I
CONDENSER EXT.
-+
SYS. MUST BE OFF
L_!EFORE T AKE-OF!._J
EMERGENCY PROCEDURES
AIR START PROCEDURE
Air conditioning system must be turned off before attempt-
ing air start procedures.
AIR CONDITIONING SYSTEM MALFUNCTION
Turn off air conditioning system.
If air conditioning system circuit breaker trips, do not reset
until the cause of the malfunction has been determined and
corrected.
NORMAL PROCEDURES
PREFLIGHT INSPECTION
NOSE SECTION
Air Conditioner Condenser - CHECK SECURITY AND AT-
TACHMENT.