Section
IV
Normal
Procedures
BEECHCRAFT Baron
58
Serial TH
773
and
After
STARTING ENGINES USING AUXILIARY POWER UNIT
1. Battery
switch
- ON
2. Alternators, Electrical, and Avionics
Equipment
- OFF
3.
Auxiliary
Power
Unit
- CONNECT
4. Auxiliary Power
Unit
- SET OUTPUT
(27.0
to
28.5
volts)
5.
Auxiliary
Power
Unit
- ON
6. Right Engine - START (use normal
start
procedures)
7.
Auxiliary
Power
Unit
- OFF (after engine has been
started)
8.
Auxiliary
Power
Unit
- DISCONNECT (before
starting
left engine)
9.
Alternator
Switches
- ON
TAXIING
Avoid taxiing
through
water,
slush or
muddy
surfaces if
possible. In cold weather,
water,
slush or mud,
when
splashed onto landing gear
mechanisms
or control surface
hinges may freeze, preventing free
movement
and
result-
ing in
structural
damage.
October
1976