Beechcraft Baron 58 - Illumination of Alternator-Out Ught (TH-773 Thru TH-1376)

Beechcraft Baron 58
514 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
BEECHCRAFT
Baron
58
Serial TH
773
and
After
Section
III
Emergency
Procedures
5. Essential Electrical Equipment - ON (Isolate defective
equipment)
NOTE
Ensure fire is out and will not be aggravated by
draft. Turn off CABIN HEAT switch and push in
the
CABIN
AIR control. Open pilot's storm
window, if required.
STARTER ENERGIZED WARNING LIGHT ILLUMINATED
(If installed)
After engine start, should the starter relay remain engaged,
the starter will remain energized and the starter energized
warning light will remain illuminated. Continuing to supply
power to the starter will result in eventual loss of electrical
power.
ON THE GROUND:
1. Battery Master and both Alternator Switches . OFF.
2. Do not take off.
IN FLIGHT
AFTER
AIR
START
1. Battery Master and both Alternator Switches - OFF.
2. Land as soon as practical.
ILLUMINATION OF ALTERNATOR OUT LIGHT
(TH-773I
thru TH-1376)
In the event of the illumination
of
a single AL TERNATOR
OUT
light:
1. Check the respective loadmeter for load indication
a. No Load - Turn off affected alternator
b. Regulate load
In the event of the illumination of both
AL TERNATOR
OUT
lights:
1. Check loadmeters for load indication
a. No load indicates failure of regulator
(1
) Switch regulators
(2) System should indicate normal
August, 1984 3-11