Section
III
Emergency Procedures
BEECHCRAFT
Baron
58
Serial TH
773
and
After
b. If condition recurs
(1) Switch to original regulator
(2)
System
returns
to
normal,
indicates
overload condition causing malfunction
(3) Reduce load
c.
If
condition
indicates
malfunction
of both
alternator circuits
(1) Both ALT Switches - OFF
(2) Minimize electrical load since only battery
power
will be available
ILLUMINATION OF ALTERNATOR - OUT LIGHT (TH-1377
AND AFTER, AND AIRPLANES EQUIPPED WITH KIT NO.
55-3024)
In the event of the illumination of a single ALTERNATOR -
OUT light:
1. Check the respective loadmeter for load indication.
a. No Load - Turn off affected alternator.
b. Regulate load to less than 100
%
of remaining
alternator.
c. Affected Alternator - ON. Check load indication.
d. No Load
- Turn affected alternator off and leave
off.
In the event of the illumination of both ALTERNATOR - OUT
lights:
1. Check loadmeters for load indication.
a. No Load - Turn both alternator switches off.
b. Reduce load to minimum (must be less than the
rating of one alternator).
c. Left Alternator
- ON. If no indication on loadmeter,
turn off and leave off.
3-12 August, 1984