SectionVIII
Handling, Serv -
Maint
OXYGEN SYSTEM
BEECHCRAFT Baron
58
SerialTH
773
and
After
WARNING
Keep hands, tools,
clothing,
and
oxygen
equip-
ment
clean
and
free
from
grease
and oil. KEEP
FIRE
AWAY
FROM OXYGEN.
1. Read
the
pressure
indicator
on
the
oxygen
console.
(The
shutoff
valve on
the
oxygen
cylinder
must
be open.) If
the
oxygen
cylinder
is
equipped
with
a gage,
system
pressure
may
be checked at
the
cylinder.
CAUTION
Always
open
the
cylinder
shutoff
valve
slowly
to
prevent
damage
to
the
system.
2.
Make
certain
that
the
oxygen
control
valve is
closed
(PUSH IN).
3.
Close
the
cylinder
shutoff
valve,
remove
the
cap
from
the
filler
va1ve, and
attach
the
recharging
outlet.
Open
valve on
supply
bottle.
4.
Open
the
cylinder
shutoff
valve
and
fill
the
cylinder
to
1800
+ 50 psi (add 3.5 psi
per
degree
above 70°F;
sub-
tract
3.5
psi per
degree
below
70°F).
5. Close
the
cylinder
shutoff
valve, close
valve
on
the
sup-
ply
bottle,
remove
the
recharging
outlet,
and
replace
the
filler
valve cap.
6. Reopen
the
cylinder
shutoff
valve to
prepare
system
for
use.
8-22
October
1976