15.2 Resetting the error E5
The error E5 must be reset after eliminating the cause of error as described below:
The error cannot be reset if the push-button for intermediate lubrication is not pushed long enough or too long.
15.3 Error output on DEUTSCH plug
An external signal lamp (max. 200 mA) can be connected to PIN 4 of the DEUTSCH plug. PIN 4 switches GND / reference potential
(see chapter 8.2.1 “Connection diagram of DEUTSCH plug male”). The occurring errors are emitted at the same time as the signal
displays. The emitted signal behaves like the red LED in the display of the device (LED lights up = “high”, LED flashes = toggle 1s).
16. Accessories
Cartridge adapter
Cartridge adapter type L Cartridge adapter type F
(for Ritter grease cartridge 400 ml) (for SYSTEM REINER*)
Article no.: 10143649 Article no.: 10143650
* SYSTEM REINER is a registered trade mark
of FUCHS LUBRITECH GmbH
Cartridges