Technical data
73
NGRM7xx_D00292_07_M_XXEN/02.2022
Analogue output (M+)
Operating principle .............................................................................................................................................................linear
Functions....................................................................................................................................................................... I
NGR
, R
NGR
Current..........................................................................0…20 mA (≤ 600 Ω), 4…20 mA (≤ 600 Ω), 0…400 μA (≤ 4 kΩ)
Voltage .........................................................................................................................0…10 V (≥ 1 kΩ), 2…10 V (≥ 1 kΩ)
Tolerance related to the current/voltage end value........................................................................................................±20 %
Ground-fault, NGR, trip relay
Switching elements.................................................................................................................................... changeover contacts
Operating mode ................................................................................................................. configurable fail-safe/non-fail-safe
Electrical endurance, number of cycles.............................................................................................................................10,000
Switching capacity............................................................................................................................................2000 VA / 150 W
Contact data acc. to IEC 60947-5-1
Rated operational voltage AC .................................................................................................................. 250 V/250 V
Utilisation category .................................................................................................................................AC-13/AC-14
Rated operational current AC........................................................................................................................... 5 A/3 A
Rated operational current AC (for UL applications)..........................................................................................3 A/3 A
Rated operational voltage DC.................................................................................................................220/110/24 V
Utilisation category................................................................................................................................................DC12
Rated operational current DC.....................................................................................................................0.1/0.2/1 A
Minimum current......................................................................................................................1 mA at AC/DC > 10 V
Environment/EMC
EMC immunity (IEC 61000-6-2 / IEC 60255-26 Ed. 3.0)..............................................................................DIN EN 61000-6-2
EMC emission (IEC 61000-6-4 / IEC 60255-26 Ed. 3.0)................................................................................DIN EN 61000-6-4
Operating temperature.........................................................................................................................................-40…+70 °C
.............................................................................................................................................-40…+60 °C (for UL applications)
Humidity ..........................................................................................................................................................................≤ 98 %
Classification of climatic conditions acc. to IEC 60721 (except condensation and formation of ice)
Stationary use (IEC 60721-3-3) ...........................................................................................................................3K23
Transport (IEC 60721-3-2).......................................................................................................2K11 (–40…+85 °C)
Long-term storage (IEC 60721-3-1) .......................................................................................1K22 (–40…+70 °C)
Classification of mechanical conditions acc. to IEC 60721 / IEC 60255-21 / DIN EN 60068-2-6
Stationary use ......................................................................................................................................................3M12
Transport ................................................................................................................................................................2M4
Long-term storage................................................................................................................................................1M12