BestCode Next Series 8 Technical Manual October 2022 Page 163 of 290
Firmware could not be loaded.
Displayed to indicate that the firmware version on the USB drive is not valid.
Erase USB and re-load correct firmware files to USB stick. Repeat Firmware Update.
Perform J-Link Firmware Load.
If issue persists, contact BestCode support or replace Main PCB.
Loading older software versions not permitted.
Displayed to indicate an attempt to load software with a lower version than what is currently installed.
Erase USB and re-load correct firmware files to USB stick. Repeat Firmware Update.
Perform J-Link Firmware Load using newest Firmware Version.
"Compatible USB required to perform firmware update."
Displayed to indicate that a USB drive is required to complete firmware installation.
Insert USB with proper Firmware file structure.
USB is damaged, replace the USB with a different stick
USB socket or driver is damaged on the Main PCB, replace the Main PCB.
"Print memory could not be saved."
Displayed to indicate that the attempt to save charge data aka Template data, failed.
"System settings have restored to factory defaults."
Displayed to indicate that factory defaults are now in effect.
"All messages will be erased."
Displayed to inform the user that all messages will be erased, except for default messages, and asks
for confirmation.
YES to delete all messages. Cancel to exit.
All graphics will be erased.
Press OK to delete all graphics.
Press Cancel to close the prompt.
Reports script name to the Event Log when run.