BestCode Next Series 8 Technical Manual October 2022 Page 69 of 290
Recommended Flight
Time Value
Recommended Flight
Time Value
The system will perform Clean
Starts and Stops when using the
Start/Stop Jet buttons on the
home screen.
The system will perform a
longer routine Start and Stops
for extra cleaning when using
the Start/Stop Jet buttons on
the home screen.
Recommended for Opaque
and Soft Pigment inks.
Disables Clean starts and
stops. All starts / stops will be
quick start / stop.
Recommended for Food
Grade and Ethanol based inks.
Printer will automatically pick a phase point.
This is the default setting and should always
be used.
Forces a phase set point between 0-16. Used for
diagnosing phase issues.
Print Select is the BCD message Select (See Remote Comm Document Here).
Allows for message changes that include
identical adjust info, and messages must be
the same Font Template.
Can switch and print Several messages per
second.
Messages changes can have unique Adjust info and
message can differ by any format.
Can switch and print about 1 message per second.
If the Phase Threshold is less than 10 or above 40, this button can be used to set it back to an
acceptable point.
Periodically circulates ink through the system,
as long as the machine is powered on. Used
for 88SOP, 88SHSOP systems and
recommended for freezer applications.
Requires machine to never be powered off.
No automatic ink stirring will occur while the jet is
off.
Enable a special sensitivity for the printhead.
Helpful in diagnosing internal printhead
failures and also for detecting problems with
line setup such as poor grounding or electrical
interference.
Can be disabled in cases where line setup is poor or
false printhead faults are occurring. As long as the
print performance and normal faults operate
correctly, this fault may be disabled.