KBW (E6) 11/2016 page 54/147
9.7.3 Light commutation and special controller functions via operation lines
You can define the switching state of up to 16 operation lines (control contacts). They are used to activate
/ deactivate special controller functions.
• Operation line “Idle mode” activates / deactivates the operating mode “Idle mode” (chap. 5.4).
• Operation lines “Light level 1” and “Light level 2” serve to turn on/off the fluorescent tubes
The other operation lines are without function.
Use the setting “Functions on/off” to configure the operation lines.
Section view.
Select the field “Functions on/off”.
“Functions on/off” entry menu.
Mark / unmark the checkbox of the desired
function to activate / deactivate it and press the
Confirm icon.
The controller returns to the section view.
Section view indicating the operation lines.
Activated operation line: switching status “1” (On)
Deactivated operation line: switching status “0” (Off)
The operation lines count from right to left.
Example:
Activated operation line “Idle mode” = 000000000000000
1
Deactivated operation line “Idle mode” = 000000000000000
0