Probus DP V1 Agile 06/201058
Parameter List
17.2 Parameters
Profibus
No. Description Units Value Range Chapter
329 DP-V1 Mode - 1 … 2 16.2
Rated Motor Parameters
375 Rated Frequency Hz 10,00 ... 1000,00 16.4.5
Profibus
390
Profibus Reference
Hz
0,00 ... 999,99
16.4.5
391 Profibus Node-ID - -1 ... 126 9
Bus Control
392 State Transition 5 - 0 ... 2 16.4.3.2
Profibus
393 Profibus Error Reaction - 0 … 3 12
Bus Control
410 Steuerwort - 0 … 0xFFFF 16.4.1
412 Local/Remote - 0 ... 44 16.4.1
Data Set change-over
414 Data Set selection - 0 ... 4 16.4.1
Frequency Ramps
424 Emergency stop clockwise Hz/s 0,01 ... 9999,99 16.4.3.1
425 Emergency stop anticlockwise Hz/s 0,01 ... 9999,99 16.4.3.1
Digital Outputs
549 Reference Value Reached:Hysteresis % 0,01 ... 20,00 16.4.2
Stopping Behavior
637 Switch-off Threshold % 0,0 ... 100,0 16.4.3.1
638 Holding Time Stop Function s 0,0 ... 200,0 16.4.3.1
Profibus
1300 In-PZD 3 Boolean - 16.3.3
.
. all In-PZD Parameter
.
1339 In-PZD 17/18 Long -
Profibus
1370 In-F-PDP-word 1 - Selection 16.4
1371 In-F-PDP-word 2 - Selection 16.4
1372 In-F-intern-long 1 - Selection 16.4
1373 In-F-intern-long 2 - Selection 16.4
1374 In-F-Convert-Reference Hz 0.01…999.99 Hz 16.4
Note:
Parameter
Data Set Selection
414 is only accessible via the communi
cation
channel of objects PPO1 and PPO2. It cannot be accessed via the Vplus PC-
Software or the Operator Panel.