Probus DP V1 Agile 6106/2010
Annex
18.2 Warning Messages Application
When the highest bit in the Warning messages is set, a “Warning Message Application” is present.
The Application warning messages are given via parameter Application Warnings 274, bit-coded
according to the following scheme.
Parameter
Application Warnings 273 shows
the warnings in clear text on the operator panel and
the PC software tool VPlus.
Use Parameter
274 to access the Application warning codes via Profibus.
Description
0 0x0001 BELT
1 0x0002 (reserved)
5 0x0020 (reserved)
6 0x0040 SERVICE
7 0x0080 User 1
11 0x0800 (reserved)
12 0x1000 (reserved)
13 0x2000 (reserved)
Note: The meaning of the individual warnings are described in detail in the operating
instructions.
18.3 Error Messages
The error
code that is stored after a fault occurs is made up of the fault group FXX (high Byte,
hexadecimal) followed by the code number XX (low Byte, hexadecimal).
F20 62 Profibus OFF (communication connection to DP Master lost)*
Communication watchdog CM-PDPV1 / inverter controller
*
This message only appears whenever
The Actual error message can also be read out by parameter access via parameter Actual Fault
260.
Parameter
Actual Error 259 shows the actual error in clear text on the operator panel and the PC
software tool VPlus.
In addition to the fault messages stated, there are further fault messages used for internal purposes
only and which are not listed here. If you receive any fault mes
sages which are not listed, please
Index
Index
A
Actual Values .......................................55, 58
Application Warnings ................................. 61
Assembly
Communication Module .......................... 11
B
Baud rate ................................................. 16
C
Commissioning.......................................... 13
Communication Channel ............................ 25
Configuration ............................................ 20
Connection ............................................... 12
Control
Contacts................................................ 42
Remote Contacts.................................... 50
Statemachine......................................... 44
Control Word ............................................ 41
Convert PDP/internal ................................. 40
D
Data set Selection ..................................... 41
Data Type
Current ................................................. 34
Daten Type
Boolean................................................. 34
Prozent ................................................. 34
Wort ..................................................... 34
Digital Inputs ............................................ 50
DP-Master IN ............................................ 55
DP-Master OUT ......................................... 55
DP-V1 Channel.......................................... 31
DP-V1 Mode.............................................. 31
E
EEPROM Access ........................................ 27
Electrical Installation
Safety ..................................................... 8
Emergency Stop Anticlockwise.................... 48
Emergency Stop Clockwise......................... 48
Error Messages ......................................... 61
F
Fault Messages ......................................... 26
H
Holding Time Stop Fct. .............................. 48
I
Input Parameters ...................................... 37
IN-PZD..................................................... 37
Internal Reference Frequency..................... 53
L
Local/Remote............................................ 41
O
Operation Mode S7 Compatible................... 33
Operation Mode Standard .......................... 32
Output Sources ......................................... 36
OUT-PZD.................................................. 36
P
Parameters ............................................... 59
PKW......................................................... 25
PPO ......................................................... 19
Profibus Error Reaction .............................. 18
Profibus Node-ID....................................... 16
Profibus Reference .................................... 53
Prozess Data Channel ................................ 34
PZD.......................................................... 34
Q
Quick Stop................................................ 48
R
RAM Access .............................................. 27
Rated Frequency ....................................... 53
Reference Bus Frequency........................... 53
Reference Ramp Frequency........................ 54
Reference Value Reached
Hysterisis .............................................. 43
Request Identification................................ 26
Response Identification.............................. 26
S
Safety ........................................................ 7
Scaling ..................................................... 39
State machine diagram .............................. 46
Station Address......................................... 16
Status Control........................................... 18
Status Fieldbus Module .............................. 18
Status Word.............................................. 41
Storage ...................................................... 7
Switch-off Threshold Stop Fct..................... 48
T
Transition 5 .............................................. 49
Transport ................................................... 7
U
USB ......................................................... 10
V
VPlus........................................................ 10
W
Warning Messages .................................... 60
Warning Messages Application.................... 61
Warnings.................................................. 60