Safety
EN
78 bora.com
PLEASE NOTE
Appliance damage caused by incorrect wiring
The electrical safety of the appliance is only guaranteed if it is connected to a
protective conductor system that has been installed in line with regulations.
u
Work on electrical components must only be conducted by trained electrical
personnel.
u
Ensure that this basic safety precaution is met. The appliance must be
suitable for the regional voltage and frequency.
u
Check the information on the identification plate and in the event of
deviations, do not connect the appliance.
u
Do not connect the appliance to the mains until the duct system has been
installed or the recirculation filter has been fitted.
u
Only use the connection cables supplied.
PLEASE NOTE
Appliance damage caused by incorrect installation clearances
Failure to adhere to installation clearances can lead to damage to the appliance
and kitchen units, as well as restricted functions.
u
During installation maintain the minimum clearance stated in the Installation
chapter.
2.4.1
Safety instructions – cooktop extractor installation
ö
DANGER
Risk of smoke inhalation
When the cooktop extractor is used in exhaust air mode, it draws in air from
the room it is installed in and from neighbouring rooms. Without sufficient air,
there will be a drop in air pressure. When used at the same time as a fireplace
that is dependent on the air in the room, noxious gases can be sucked into the
living areas from the chimney or outlet shaft.
u
Make sure that there is always a sufficient air supply.
u
Only use reliable, tried-and-tested switching devices, (e.g. window contact
switch, low pressure warning device) and have them approved by a qualified
expert (certified chimney sweep).