Troubleshooting
EN
bora.com 109
8 Troubleshooting
You can often remedy faults and errors yourself. This saves time and money as you don’t need to call out
customer services.
u
Observe all safety and warning information (see"2Safety").
Operating situation Cause Remedy
Appliance cannot be switched on
Fuse/automatic circuit breaker defective
Replace the fuse;
Switch the automatic circuit breaker
back on
The fuse/automatic circuit breaker trips
several times
BORA Contact the Service Team.
The power supply is disconnected Have a specialist electrician inspect the
power supply
Odour formation when operating a new
appliance
This is normal with brand new
appliances
Odours stop forming after a few
operating hours
A cooking zone display shows
No or unsuitable cookware Use suitable, appropriately sized cook-
ware (see “Appliance description”)
The lock button lights up
Active child lock deactivate the child lock
Cooking zone/cooktop switches off
automatically
The maximum cooking zone operating
time has been exceeded
Put the cooking zone back into
operation
Power setting prematurely cancelled The overheating protection has tripped
see"5.7.6Overheating protection"
The cooktop cooling fan continues to run
when the cooktop has been switched off
The cooling fan runs until the cooktop
has cooled
Wait until the cooling fan switches off
automatically
Decreased extraction performance of
the cooktop extractor
Grease filter extremely dirty Clean or replace the grease filter
Activated charcoal filter extremely dirty
(recirculation only)
Replace the activated charcoal filter
Item in air guiding housing
(e.g. cleaning cloth)
Remove the object
or is displayed
Use of a phase-separating window
contact switch
Open the window
Fan defective or a duct connection has
become loose
BORA Contact the Service Team
is displayed
The overheating protection has tripped
see"5.7.6Overheating protection"
is displayed
Object on the operating panel Remove the object from the operating
panel
The operating panel is dirty Clean the operating panel
is shown (recirculation only)
End of activated charcoal filter service
life reached
Insert a new activated charcoal filter
(see"7.6Replace the activated char-
coal filter").
Tab.8.1
Troubleshooting
Faults and errors not covered:
u
Switch off the appliance.
u
Contact the BORA Service Team Team (see see"11Warranty, technical service, spare parts, accessories") and
enter the error number displayed and the appliance type.

Table of Contents