1 689 989 403 2019-03-01| Robert Bosch GmbH
Special accessories | Denoxtronic 1.1 | 27 en
4.4 ESD protective equipment
i ESD (electrostatic discharge) that for example can
arise from rubbing against clothing can destroy
electronic devices or components when the ESD is
released by touching.
! Whenever work is performed on the supply module,
in particular near exposed printed circuit boards for
supply pumps, a protective device against ESD (see
the example in fig. 15) must be worn on the wrist
with a grounded connection to the mains voltage
system.
Fig. 15: ESD wrist strap
i Various ESD wrist strap designs exist in with plugs
appropriate for the specific country.
5. Lubricants and auxiliary
materials
5.1 Forming gas 5
i Only use forming gas 5 of the following composition:
5% H2 (hydrogen), 95% N2 (nitrogen).
! Observe the safety data sheet for forming gas 5.
! The person performing the test must have re-
ceived instructions in the handling of pressurized
gases.
! The test pressure must not exceed 4,5bar.
! Only use and store forming gas 5 containers in
well-ventilated spaces.
! Check each new delivery for compliance with the
specified composition (5% H2, 95% N2). Check
the label on the gas canister.
! Tampering with components relevant to safety
(e.g. pressure-reducing valves, safety valves) may
lead to severe accidents and personal injury and
is forbidden.
Affix/check warning
Affix the warning sticker on the composition of form-
ing gas 5 provided with the tester set 0986610551
to the side of the test device 0986613880 near the
forming gas container (see fig.12, item2).
! Regularly check to ensure that the warning sticker
is not damaged. If the warning sticker is dam-
aged, replace it immediately.
i Detailed instructions on use can be found in
the separate ESI[tronic] repair instructions
Denoxtronic 1.1, in particular in the chapter
"Safety instructions" under the sections "Forming
gas5" and "Lubricants and auxiliary materials".