EasyManua.ls Logo

Bosch Denoxtronic 1.1 - Maintenance; Check Exhaust Gas Sampling Hoses; Calibrating the Scale 0 986 610 838

Bosch Denoxtronic 1.1
382 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1 689 989 403 2019-03-01| Robert Bosch GmbH
28 | Denoxtronic 1.1 | Lubricants and auxiliary materialsen
5.2 Denoxtronic test solution
Denoxtronic test the solution consists of 99% distilled
water with 1% anti-corrosive agent
P3-prevox7400. The solution can be mixed by the user
or purchased as a ready-to-use test solution.
! Only use a mixture of P3-prevox 7400 (1%) and dis-
tilled water (99%). It is impermissible to use AdBlue
or just water.
i The test solution has a limited shelf life and there-
fore needs to be replaced every eight weeks.
i Dispose of the test solution in compliance with re-
gional disposal and environmental regulations
! Observe the safety data sheet for P3-Prevox 7400.
i Detailed instructions on use can be found in the sep-
arate ESI[tronic] repair instructions Denoxtronic 1.1,
in particular in the chapter "Safety instructions"
under the sections "Safety instructions" and "Lubri-
cants and auxiliary materials".
6. Maintenance
6.1 Check exhaust gas sampling hoses
All of the hose lines must be handled carefully and
checked before use. Hoses are to be replaced if check-
ing reveals the following damage:
R Cracks, brittle areas, abrasion or blistering of the
hose jacket
R Kinked exhaust gas sampling hose
R Stiff union nuts or quick-release couplings
R Deformed or damaged connection end of hose line
(sealing cone, plug-in nipple, etc.)
R Leakage at hose fixture
R Corrosion at hose fixture if strength is reduced as a
result
! Damaged exhaust gas sampling hose lines must not
be repaired.
6.2 Calibrating the scale 0986610838
i The weight 0986610839 must be used to calibrate
the scale.
Procedure:
1. Use <ON/TARE> to switch on the scale.
2. Press and hold <OFF> until the display shows CAL.
3. Release <OFF>. The display will show the value of
the required balance weight.
4. Place the balance weight 0986610839 on the cen-
ter of the plate.
5. The display will briefly show F. Then, the scale will
switch off.
6. Remove the balance weight 0986610839 from the
plate.
" The calibration will be complete, and the scale will be
ready for operation again.
i In case of a calibration error or incorrect balance wight,
E will appear on the display. Repeat calibration.
6.3 Check weight 0 986 610 839
Have the weight checked every two years by a recog-
nized workshop.

Table of Contents

Related product manuals