Installation Manual Comms Programming
9-18
Bosch Security Systems 07/14 BLCC610I
Comms > MyAlarm >
Email Options
-
MENU 5-5-9
1 Open Close Y
2 Zones Y
3 System Y
4 Access Y
5 Reserved N
6 Reserved N
7 Reserved N
8 Reserved N
This menu allows the master user to select which event
types will be reported using the email reporting function.
By default the first 4 options are set to report via email.
Follow the procedure below to configure the required
options.
1) Enter your Master PIN + [MENU].
2) Enter [5] + [5] + [9] + [OK].
The keypad will display the list of current options.
Options with a preceeding tick mark are selected.
Open Close
Zones
System
Press
 OK ON OFF MENU
3) Use the [] and [] keys to highlight the feature that
you want to program, then use the [ON] and [OFF]
keys to turn on and off the features as required.
4) When all email options are programmed, press [OK]
to save and exit, or press [MENU] to exit without
saving.
Open Close
This option allows the control panel to report open and
close reports via email.
Zones
This option allows the control panel to report zone ‘alarm
and ‘trouble' reports via email.
System
This option allows the control panel to report via email
numerous system reports (e.g. AC Fail, Low Battery etc)
via email.
Access
This option allows the control panel to report via email
when a valid token has been swiped eg. Access Granted’
or ‘Access Denied’.
Comms > IP Reporting >
Receiver IP
MENU 5-6-0
Dest Nº 1
1 Digits 12
0 0 0 0 0 0 0 0 0 0 0 0
Dest Nº 2
1 Digits 12
0 0 0 0 0 0 0 0 0 0 0 0
This menu allows the installer to program the TCP IP
address for Destination 1 and/or Destination 2 so that
the control panel can communicate to the base station
receiver.
1) Press [MENU] + [5] + [6] + [0]. The keypad will
prompt you to select which destination
(destination 1 or 2) that you want to program the
base staion IP addrress.
Rr1 Dest 1
Rr2 Dest 2
Exit
Press
 OK or MENU
2) Highlight the destination number (1 or 2) required,
then press [OK]to select.
3) The keypad will display the first six digits of the
base station IP address.
Receiver IP Rr1
000000000000
Press 0-9 OK to SAVE
4) Use the numeric keys [0] to [9] + [] and [] keys
to program the new MyAlarm IP Address, then
press [OK] to save and exit or press [MENU] to exit
without saving.

Table of Contents

Other manuals for Bosch SOLUTION 6000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch SOLUTION 6000 and is the answer not in the manual?

Bosch SOLUTION 6000 Specifications

General IconGeneral
Partitions8
System TypeHybrid wired/wireless security system
KeypadsUp to 16
CommunicationPSTN, optional IP module, optional GSM/GPRS module
Arming ModesStay, Away
Power Supply16.5VAC
Backup Battery12V 7Ah
Operating Temperature0°C to +50°C

Related product manuals