EasyManuals Logo

Bosch SOLUTION 6000 Installation Guide

Bosch SOLUTION 6000
172 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #139 background imageLoading...
Page #139 background image
Solution 6000
Installation Manual Device Programming
10-15
Bosch Security Systems 07/14 BLCC610I
Devices > GSM/GPRS Module >
SMS Control
-
MENU 6-5-6
Phone 1
1 Digits 16
Phone 2
1 Digits 16
Phone 3
1 Digits 16
Phone 4
1 Digits 16
Phone 5
1 Digits 16
Phone 6
1 Digits 16
Phone 7
1 Digits 16
Phone 8
1 Digits 16
Phone 9
1 Digits 16
Phone 10
1 Digits 16
(GSM MODULE REQUIRED) The SMS control table allows
you to program up to 10 telphone numbers that the
control panel will automatically identify when you send
SMS commands to operate the control panel.
1) Enter [MENU] + [6] + [5] + [6]. The keypad will
display the following:
Phone 1=
Phone 2=
Phone 3=
Press  OK or MENU
2) Highlight the telephone number that you want to
restrict for SMS control, then press [OK] to select.
SMS Control Phone 1
Press  0-9 OK to SAVE
3) Using the numeric keys, enter the telephone
number that you wish to program.
4) Press [OK] to save and return to the restrict SMS
control table, otherwise press [MENU] to exit
without saving.
Devices > Ethernet Module >
Module IP Address
MENU 6-6-0
1 Digits 12
0 0 0 0 0 0 0 0 0 0 0 0
This is the IP address of the TCP/IP module on the
customers internal local area network.
1) Press [MENU] + [6] + [6] + [0]. The keypad will
display the current IP address.
Module IP Address
000000000000
Press 0-9 OK to SAVE
2) Use the numeric keys [0] to [9] + [] and [] keys
to program the IP Address, then press [OK] to save
and exit or press [MENU] to exit without saving.
Devices > Ethernet Module >
Subnet Mask
MENU 6-6-1
1 Digits 12
0 0 0 0 0 0 0 0 0 0 0 0
The can be found by running IPCONFIG on a PC
connected to the clients network. Typical subnet mask is
255.255.255.0.
1) Press [MENU] + [6] + [6] + [1]. The keypad will
display the current subnet mask.
Subnet Mask
000000000000
Press 0-9 OK to SAVE
2) Use the numeric keys [0] to [9] + [] and [] keys
to program the 12 digit subnet mask number, then
press [OK] to save and exit or press [MENU] to exit
without saving.

Table of Contents

Other manuals for Bosch SOLUTION 6000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch SOLUTION 6000 and is the answer not in the manual?

Bosch SOLUTION 6000 Specifications

General IconGeneral
Partitions8
System TypeHybrid wired/wireless security system
KeypadsUp to 16
CommunicationPSTN, optional IP module, optional GSM/GPRS module
Arming ModesStay, Away
Power Supply16.5VAC
Backup Battery12V 7Ah
Operating Temperature0°C to +50°C