Solution 6000
Installation Manual System Programming
11-4
Bosch Security Systems 07/14 BLCC610I
Some other examples of the log are as follows:
1)
E202 Sun,01Apr 03:41:45
Disarmed by User
Area 1 Name
Ur1 User 1 Name
E202 Dest= SLL-----
Kp1 Keypad 1 Name
Panel 1
Dest 1 at 01-Apr 03:41:57
2)
E405 Sun,01Apr 06:41:45
Burglary Zone Bypassed
Area 1 Name
Zn3 Zone 3 Name
E405 Dest= SLL-----
Ur1 User 1 Name
Panel 1
Dest 1 at 01-Apr 06:41:57
The Dest= field displays the various reporting route
information for up to eight different reporting
destinations. Your installer will have configured these
during installation.
The following letters will be displayed in the eight
destination locations indicating the status of the report.
The log will also show the actual time a report was sent.
Dest =
S = Sent
L = Logged
P = Pending
F = Failed
A = Aborted
System > Commands >
Domestic Default
MENU 7-0-3
This command will configure the control panel for
Domestic format reporting (eg. mobile telephones
etc). All alarm restore reports and open/close reporting
options will be automatically disabled. Therefore, only
emergency, burglary and fire reports will be sent.
The following table list the changes that will occur when
you select domestic default using MENU 7-0-3.
Program Option Domestic Default Value
All Trouble Reports Disabled
All Bypass Reports Disabled
All Restore Reports Disabled
Destination 1 TX Format Domestic Reporting
Access Route Log Only
Open / Close Reports Log Only
Test Route Log Only
System Route Log Only
Table 33: Domestic Default Settings
1) Press [MENU] + [7] + [0] + [3]. The keypad will
display:
To RECONFIGURE all panel
dialler programming to
DOMESTIC, Press OK. or To
Cancel,Press MENU.
2) Press [OK] to start the default process or press
[MENU] to cancel and exit.
3) The keypad will display the following message
during the default process and will exit back to the
menu when finished.
Defaulting System
..Please Wait..
System > Commands >
Factory Default
MENU 7-0-4
This command will erase ALL programmable data and
return the control panel to factory default settings.
Defaulting the panel will NOT erase any history events
that are currently stored in the panel.
i
Note
During a factory default both the Status and Dialler
LED indicators on the panel will flash very quickly to
indicate defaulting is still in progress.
1) Press [MENU] + [7] + [0] + [4]. The keypad will
display:

Table of Contents

Other manuals for Bosch SOLUTION 6000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch SOLUTION 6000 and is the answer not in the manual?

Bosch SOLUTION 6000 Specifications

General IconGeneral
Partitions8
System TypeHybrid wired/wireless security system
KeypadsUp to 16
CommunicationPSTN, optional IP module, optional GSM/GPRS module
Arming ModesStay, Away
Power Supply16.5VAC
Backup Battery12V 7Ah
Operating Temperature0°C to +50°C