Solution 6000
Installation Manual Programming Overview
4-3
Bosch Security Systems 07/14 BLCC610I
SERVICE MODE
Service mode when activated disables dialler reporting,
prevents all alarms and prevents all users from arming the
system.
Turning Service Mode ON
1) Enter programming mode.
[1][2][3][4] + [MENU]
2) Turn service mode on.
[MENU] [7][0][8]
3) Follow display prompts.
4) Hold down [MENU] to exit.
i
Note
Keypads will display the word “SERVICE” in the middle
of the display when service mode is active.
Turning Service Mode OFF
1) Enter programming mode.
[1][2][3][4] + [MENU]
2) Turn service mode on.
[MENU] [7][0][8]
3) Follow display prompts.
4) Hold down [MENU] to exit.
i
Note
You must exit Service Mode to reactivate the system.
Service mode will automatically exit after 2 hours.
DEFAULTING THE SYSTEM
Defaulting the system will reset all programming options
back to the factory default setting. All programming
information will be erased.
Hardware Default
1) Remove all power to the system - AC and battery.
2) Press and hold the default push button, then apply
power to the control panel.
3) Release the default button, The panel will reset and
revert to normal operation when default is
complete.
Software Default
1) Enter programming mode.
[1][2][3][4] + [MENU]
2) Select factory default option.
MENU 7-0-4
3) The panel will reset and revert to normal operation
when the default is complete.
i
Note
An optional CM255B Default Key may be purchased
to unlock both the Installer PIN and RAS Security
PIN. The default key is single use only. Refer to the
CM255B instructions for additional information.
i
Note
You can disable factory defaulting using MENU 7-7-
4. If factory defaulting has been disabled you must
know the installer PIN to perform a factory default
otherwise the system will need to be returned to
your supplier for defaulting or you can purchase a
CM255B Default Unlock Key which will unlock the
panel in the field. Charges will apply for defaulting if
returned to the distrubutor.
TRIGGERING A DURESS ALARM
If your PIN is 2580, to send a duress report when the area is off,
Enter, [2][5][8][0] + [8][0] + [OK] or [ON].
If your PIN is 2580, to send a duress report when the area is on,
Enter, [2][5][8][0] + [8][0] + [OFF].
i
Note
Duress alarms are triggered by entering the user PIN
followed by the last 2 digits of the user PIN followed
by the ON or OFF key.
DOMESTIC TEMPLATE DEFAULTS
The following table list the changes that will occur when
you select domestic default. See MENU 7-0-3 — Domestic
Default.
Program Option Domestic Default Value
All Trouble Reports Disabled
All Bypass Reports Disabled
All Restore Reports Disabled
Destination 1 TX Format Domestic Reporting
Access Route Log Only
Open / Close Reports Log Only
Test Route Log Only
System Route Log Only
Table 15: Domestic Reporting Defaults
DIRECT LINK PROGRAMMING
The panel can be programmed via the Solution Link™
Upload/Download software in either Direct Link or
Remote Link modes. For Direct Link you will need a CM900
Direct Link module which is used to connect the panels
serial port to the PC.
Once the cable is connected you will need to hold down
the default switch on the panel for 5 seconds to initiate
the programming session. See the board layout drawings
in Section 3 of this manual for the default switch location.

Table of Contents

Other manuals for Bosch SOLUTION 6000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch SOLUTION 6000 and is the answer not in the manual?

Bosch SOLUTION 6000 Specifications

General IconGeneral
Partitions8
System TypeHybrid wired/wireless security system
KeypadsUp to 16
CommunicationPSTN, optional IP module, optional GSM/GPRS module
Arming ModesStay, Away
Power Supply16.5VAC
Backup Battery12V 7Ah
Operating Temperature0°C to +50°C