Solution 6000
Installation Manual System Programming
11-10
Bosch Security Systems 07/14 BLCC610I
System > Siren >
Siren Swinger
MENU 7-4-3
(*** System Wide Parameter ***)
0
3
This menu allows you to program how many times a zone
programmed for Lockout Siren can sound the siren during
each arming cycle.
At default, zones programmed for Lockout Siren will be
able to trigger the siren 3 times before being locked out.
The count will be reset when the system or area is next
disarmed.
1) Press [MENU] + [7] + [4] + [3]. The keypad will
display the current Swinger Siren count.
Siren Swinger
3
Press 0-9 OK to SAVE
2) Using the numeric keys, enter the new swinger
siren count. Valid entries are 0 to 15 where 0 =
unlimited.
3) Press [OK] to save and exit or press [MENU] to exit
without saving.
TIMEZONES
The control panel has 2 fixed timezones (Tz0 - Disabled and
Tz1 - 24 Hr TimeZone) and 15 programmable timezones.
A timezone is created by setting up a valid time period
that becomes TRUE whenever the time is equal to or after
the start time and before the end time for the selected
day.
There are 2 default timezones created within the system
that cannot be changed. These are Tz0 = Disabled - which
is FALSE 24/7 and Tz1 = 24 Hour which is TRUE 24/7 (TZ1
being the opposite of Tz0). Tz2 to 16 are configurable to
reflect any operation time and day as required to operate,
restrict, or control when something happens. Please
refer to the following table that illustrates the effect of
assigning timezones.
Assigned To Tz0 (Disabled) Resulting Effect
Door No access
Door Lock Will never unlock
Door Group No access
Egress Will never trigger
Auto Arming Will never arm (Same as Tz1)
Output Will never trigger
Assigned To Tz1 (24 Hr) Resulting Effect
Door Full 24 hr access
Door Lock Unlocked 24 hrs
Door Group Full 24 hr access
Egress Operates 24 hrs
Auto Arming Will never arm (Same as Tz0)
Output Always triggered
Table 35: Fixed Timezones (Tz0 & Tz1)
In previous versions, events programmed to follow
timezones may fail to operate if the automatic test
report option has been enabled. In version 2.14, this
has been corrected.