2-31
Confidential
Error code 0600
A communication error occurred between the ASIC controlled by engine and the motor
driver.
Error code 0900
Detected irregular power supply for more than 100 times.
Print Unable 06
Turn the power off and then back on again.
Step Cause Remedy
1
Main PCB failure Replace the main PCB ASSY.
Print Unable 09
Turn the power off and then back on again.
<User Check>
Turn OFF the power switch. After several seconds, turn ON the power again and check
that this error is reset.
Step Cause Remedy
1
Low-voltage power supply PCB
failure
Replace the low-voltage power supply PCB
ASSY. Refer to “1.3.20 Reset irregular power
supply detection counter of low-voltage power
supply PCB (function code: 88)” in Chapter 5 to
reset the irregular power supply detection
counter.
2
Main PCB failure Replace the main PCB ASSY.
Note:
The irregular power supply detection error of the low-voltage power supply PCB (error
code: 0900) occurs when there is a large distortion in the power supply voltage
supplied to the machine. In this case, if the same power supply is used, the same error
may occur even when the low-voltage power supply PCB ASSY is replaced. Ask the
user to review the installation environment.

Table of Contents

Other manuals for Brother HL-2560DN

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Brother HL-2560DN and is the answer not in the manual?

Brother HL-2560DN Specifications

General IconGeneral
BrandBrother
ModelHL-2560DN
CategoryPrinter
LanguageEnglish

Related product manuals