EasyManuals Logo

Brother HL-2560DN Service Manual

Brother HL-2560DN
205 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #55 background imageLoading...
Page #55 background image
2-37
Confidential
Error code 6901
An error occurred in the fuser unit when the power switch was turned ON or sleep mode was
released.
Error code 6902
Rechecking the error after the power switch was turned OFF and then ON again because an
error was detected in the fuser unit.
(This message is displayed for approximately 15 minutes when the machine is restarted after
error code 6901 has occurred.)
Self-Diagnostic
Turn the power off, then on again. Leave the machine for 15 min.
Self-Diagnostic
Will Automatically Restart within 15 minutes.
Step Cause Remedy
1
Connection failure of each fuser
unit harness
Reconnect each harness of the fuser unit.
2
Connection failure of the eject
sensor PCB flat cable
Reconnect the eject sensor PCB flat cable.
3
Fuser unit failure Replace the fuser unit.
4
Eject sensor PCB failure Replace the eject sensor PCB ASSY.
5
Low-voltage power supply PCB
failure
Replace the low-voltage power supply PCB
ASSY.
6
Main PCB failure Replace the main PCB ASSY.
Note:
Turn OFF the power switch. After the fuser unit has cooled sufficiently, turn ON the
power switch again and leave the machine for 15 minutes. This problem may then be
cleared.
To release the fuser unit error after taking appropriate measures, enter the
maintenance mode once and quit it with the maintenance code 99.

Table of Contents

Other manuals for Brother HL-2560DN

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Brother HL-2560DN and is the answer not in the manual?

Brother HL-2560DN Specifications

General IconGeneral
BrandBrother
ModelHL-2560DN
CategoryPrinter
LanguageEnglish

Related product manuals