3-38
Confidential
■ Error code E1
Main PCB failure
■ Error code E2
Central temperature of heat roller exceeds 280°C
■ Error code E6
EEPROM error
■ Error code EB
The data reading error for E2PROM.
Print Unable E1
Turn the power off and then back on again.
Step Cause Remedy
1 Main PCB failure Replace the main PCB ASSY.
Fuser Error
Turn the power off, then on again. Leave the machine for 15 min.
Step Cause Remedy
1 Fuser unit failure Replace the fuser unit.
2 Main PCB failure Replace the main PCB ASSY.
Init Unable E6
See Troubleshooting and routine maintenance chapter in User's
Guide.
Step Cause Remedy
1 Main PCB failure Replace the main PCB ASSY.
Print Unable EB
Turn the power off and then back on again.
Step Cause Remedy
1 Main PCB failure Replace the main PCB ASSY.