Loading...
App. 4-27 Confidential
WSW24 (TAD setting 2)
Selector
No.
Function Setting and Specifications
1
2
Maximum OGM recording time
No. 1 2
0 0 : 15 sec.
0 1 : 20 sec.
1 0 : 30 sec.
1 1 : 50 sec.
3
4
Time length from CML ON
to start of pseudo ring
backtone transmission
No. 3 4
0 0 : 4 sec.
0 1 : 2 sec.
1 0 : 6 sec.
1 1 : 8 sec.
5
|
8
Attenuator for playback of
ICM/OGM to the line
(Selectable from the range of
0-15 dB)
0: 0 dB 1: 8 dB
0: 0 dB 1: 4 dB
0: 0 dB 1: 2 dB
0: 0 dB 1: 1 dB
Selectors 1 and 2: Maximum OGM recording time
These selectors set the allowable maximum recording time for an OGM.
Selectors 3 and 4: Time length from CML ON to start of pseudo ring backtone transmission
These selectors set the length of time from CML-ON up to the start of pseudo ring backtone
transmission.
In models with OGM facilities, the settings made by these selectors also apply to the length of time
from CML-ON up to the start of OGM transmission.
Selectors 5 through 8: Attenuator for playback of ICM/OGM to the line
Setting two or more selectors to "1" produces addition of attenuation assigned to each selector.
This setting is not limited by selector 8 of WSW23.