5-23 Confidential
5.1.5 Control Panel ASSY and Scanner Open Sensor Actuator
MFC640CW/DCP340CW
(1) Turn the scanner cover (scanner unit) upside down, push the left side outwards, and take out
the panel-main harness.
(2) Remove the three screws from the underside of the scanner cover.
(3) Pull up the rear end of the control panel ASSY and take it off the scanner cover.
Cable guides
Cable guides
Control panel ASSY
placed upside down
Control panel ASSY
placed upside down
Panel-main harness
Square opening
Control panel ASSY
Scanner cover
(Scanner unit)
Taptite, cup B
M3x10
Ribs
Rib
Routing the panel-main harness on the underside
of the control panel ASSY
MFC640CW
DCP340CW