III- 5
3.4 DISASSEMBLY PROCEDURE
[ 1 ] Removing the Top Cover ASSY and Thermal Tape
Note: Turn on the power supply with top cover closed and initialize the machine before
disassembly.
(1) Turn off the power supply and remove the AC cord.
Note: Disconnect the AC cord from the outlet.
Fig. 3.1-1 Removing the Top Cover ASSY and Thermal Tape (1)
(2) Pull the release levers L and R upwards and open the top cover ASSY.
(3) Remove the thermal tape from the machine.
Fig. 3.1-2 Removing the Top Cover ASSY and Thermal Tape (2)
Thermal tape
Release lever R
Top cover ASSY
Power button
A
C cord
Release lever L