48 T401S Indicator User Instructions
Supervisor menu
8.3 Counting application supervisor menu
Figure 8.3 shows the Supervisor menu when you are in the Counting application:
Figure 8.3 Supervisor menu for the Count application
Follow these steps to set the items in the Supervisor menu.
8.3.1 Count
Super Setpoint Count
1. With the Count application active, access the Supervisor menu using password
1793. Refer to Accessing the menus on page 25 for instructions. From SuPEr,
press SELECT
SEtPnt is displayed.
Count
Super
Setpnt
Edit Print Reset
No
Yes
Battery
Enable
Tmout
Off
On
Port 1
Port 2
Out1 Out2 Out3
In1
In2
In3
None
Print
Units
Select Tar e
Zero
F1
Accu
PrntHld
User
Off
On
Annun
Prt Tot Tot Fmt Clr Tot
Reset
Off
On
No
Yes
Off
On
Bold boxes and text
denote defaults.
1-3600
minutes
Key
in
value
Key
in
value
Key
in
value
Enter Print
format #
for Total
operation
SELECT =
TARE =
PRINT =
UNITS =
ZERO =
F1 = Escape or
The Setpnt and bAttErY submenus in Figure 8.3 are the same as described in
General Weighing application supervisor menu on page 40. Go there for information
on those submenus. The unique submenus to this application are described below.
The cnt Acc submenu is the same described in the Accum submenu in the
Accumulator application. Refer to step 3 on page 46.