56 T401S Indicator User Instructions
Supervisor menu
8.5.2 Notes on batching
If MODE is set to AUTO, the batch process will continue until the final ingredient is
completed. Between each ingredient there will be a slight delay to allow for motion and
final weight.
If MODE is set to MANUAL, this requires that you press F1 between each ingredient
to complete the fill cycle.
If DISP is set to NET, an autotare will occur prior to each ingredient and the Out 1, 2
and 3 fill weights will be based on Net weight.
If DISP is set to GROSS, no autotare will occur and the Out 1, 2 and 3 fill weights would
be based on the Gross weight of the accumulated ingredients. If Ingredient 1 amount
is 10, Ingredient 2 amount is 20 and ingredient 3 amount is 30 then you would enter
Out 1 = 10, Out 2 = 30 (10 + 20) and Out 3 = 60 (10 + 20 + 30). Output setpoints are
based on the actual displayed Gross weight so if inaccurate amounts of ingredient are
experienced during the batch then it may affect the amount of each subsequent
ingredient that is added.