50 T401S Indicator User Instructions
Supervisor menu
Clear total
Count Print Total Total Format Clear Total
9. Press UNITS
cLr tot is displayed. This stands for clear total. Choose on to enable
clearing the accumulated total when printed. Choose oFF to disable this
function.
If enabled, the total is cleared if the user presses and holds the PRINT
key for three seconds. The message cLr-tot will flash. The total is
printed prior to clearing if this was enabled in step 5 above.
10. Press SELECT
The current setting is displayed.
11. Press UNITS to toggle between the choices and when your choice is
displayed, press ZERO to accept …
cLr tot is displayed.
Reset
Accum Print Total Total Format Clear Total Reset
12. Press UNITS
rESEt is displayed. Use this to reset the all the items under count to the
factory defaults.
13. Press SELECT
no is displayed.
14. Press ZERO to abort the reset or press UNITS
YES is displayed.
15. Press ZERO to reset the settings to factory defaults …
rESEt is displayed.
16. Press TARE
count is displayed.
17. Press UNITS
bAttErY is displayed. The battery menu is identical in all the
applications. Refer to step 1 on page 43 for information on setting up the
battery.
18. This completes the Supervisor menu for the Accumulation application.
Repeatedly press TARE until the indicator returns to normal weighing mode.
The current weight value is displayed.