Malfunctions
Behavior in Case of Malfunction
SnackFix 2016-08 97
10.2 Behavior in Case of Malfunction
The following basically applies:
1.
In case of malfunctions that pose a direct hazard for persons or
property, immediately set off emergency stop.
2.
Determine the cause of malfunction.
3.
If it is necessary to work within the hazard zone in order to re-
move the malfunction, switch the machine off and secure against
restarting. Immediately inform the responsible person on site
about the malfunction.
4.
You can either have the malfunction be removed by authorized
technical employee or remove it by yourself - depending on the
kind of malfunction.
The malfunction chart below gives information about who
is authorized for malfunction removal.
10.3 Malfunction signal
The following facilities show errors:
in the display
blinking illuminated pushbutton [RESET]
10.4 Acknowledge malfunction
Fig. 37: Illuminated pushbutton
[RESET]
Acknowledge malfunction
Errors which can be acknowledged after error elimination
are displayed by a blinking reset-illuminated pushbutton.
If error continues to occur, contact a technical
employee/technician or an electrician.
1. Eliminate error.
2. Press blinking illuminated pushbutton [RESET].
Illuminated pushbutton [RESET] goes out.