77
77
EN
Regeneration time
Audible alarm No
High-ow No
AQA Stop Yes
Sensor No
Rinse / Hygiene No
AQA Watch Yes
Filter No
Screensaver Yes
AQA Stop trigger volume 9999 l
Unit set-up - customer
High-owoperation
Function cannot be set
AQA Stop
Floor sensor for detecting moisture in conjunction
with water volume monitoring.
AQA Stop trigger volume
Congurablewatervolumewhich,oncereached,
will trigger the water supply to be shut off.
Sensor
Function cannot be set
Rinse / Hygiene
R: The rinse function is an additional soft
water rinse, which is recommended for
operation with dwownstream reverse
osmosis, steam generator etc.
H: Asanitizingushingofbothexchanger
columnsafter24hwithnowaterow
R+H: Both functions active
AQA Watch
The AQA Watch function monitors the building’s
water supply system for consistently low
(< 60l /h) ow rates (consistently low ow rates
indicateaprobleminthepipelinenetwork).
The control unit issues a warning if an error occurs.
The CIC contact opens in the event of an error or a
power failure. (Max. contact assignment: DC 24 V,
0.5A.)
Filter
Aremindertochangeorbackushthelterelement
every6months,ltertypeBackwash,E1orChange
can be selected
Screensaver
Appears after 15 minutes of inactivity
Switch on/off