CAB Hermes Series - Printer Operational Specifications; Transfer Ribbon and Control Panel; Dimensions, Weight, and Environment

CAB Hermes Series
71 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
13cab - Produkttechnik GmbH
Transfer ribbon : Type : Hermes 4N/5N : preferably ribbons designed for the
use with near edge printheads
Hermes 4F/5F : standard ribbons
Length : 1476' in (450 m)
1968' in (600 m) on inquiry
Width : max. 4.3 in (110 mm)
Core diameter : 1 in (25 mm)
Max. roll diameter : 3.6 in (92 mm)
Colour : inside or outside
Control panel : 4 Function keys with LED display
Backlit LCD with 2 lines of text, 16 characters per line
LCD can be set to display in 8 different languages
Control features : Print stop and error message at the LCD display at
- Paper out
- Ribbon out
- Printhead/ Transport system open
Information via peripheral interface and warning light at
- passing the adjusted minimum diameter of the supply roll of
labels or transfer ribbon (if the warning sensors are installed)
Dimensions : Hermes 4N/4F : Heigth : 15.4 in (390 mm), Width : 10.9 in (277 mm),
Depth :16.5 in (420 mm)
Hermes 5N/5F : Heigth : 21.3 in (542 mm), Width : 10.9 in (277 mm),
Depth : 21.3 in (542 mm)
Weight : Hermes 4N/4F : 46.3 lb. (21 kg)
Hermes 5N/5F : 55.2 lb. (25 kg)
Operating voltage : Switcheable between 230 V A.C/ 50 Hz or 115 V A.C/ 60 Hz
Maximum 1,5 A (at 230 V) / 3 A (at 115 V)
power input :
Circuit protection : T 4 A (at 230 V) / T 6.3 A (at 115 V)
Environment : Operation at 50° to 95°F (10° to 35°C) at a humidity of 30 to 85%
Transport at -13° to 158°F (-25° to +70°C) at a max. humidity of 95%
non-condensing
Storage at 41° to 104°F (5° to 40°C) at a humidity of 5 bis 85%