100 APOLLO Digital Broadcast Production Console Panel Options
RTW TM7 METER - MU5993
The MU5993 console up-stand
panel is fitted with an RTW TM7
meter, providing a visual surround
field representation along with
comprehensive surround phase
monitoring and other features such
as loudness metering and optional
moving coil meter emulation.
Multiple types of metering instruments
can be displayed simultaneously on each
TM7 meter, the layout and sizing of each
element is configurable. The images on
this page show examples of meter types
and layouts available. For full details on
TM7 functions, please refer to the RTW
website. Multiple meter panels can be
fitted into a control surface if required.
The TM7 is supplied with 8 balanced
analogue inputs, 8 AES digital inputs
and 8 digital outputs. Digital I/O can be
supplied as either 75 Ohm unbalanced
AES3id on a BNC connector interface, or
as 110 Ohm balanced AES3 on a D-type
connector interface. Digital I/O format for
the TM7 should be specified at the time
of order.
The TM7 does not access Calrec meter
data, it requires audio feeds via the
console's rear interface panel. If the
meter is to be fed directly from console
outputs, this should be provisioned for
in the quantity of Hydra2 output ports
ordered.
Being 195mm [7.68'] wide, this panel is
often located next to the RT5707 reset
/ facilities panel, the two panels having a
combined width of 250mm [9.84'] - the
same as standard panels such as faders,
assignable's and up-stand TFT panels.
Connections
Analogue inputs are on a 25 pin female
D-Type, AES I/O is either on a 25 pin
female D-Type if balanced, or on BNC's
if unbalanced, depending on the type
ordered.