EasyManuals Logo

Cambium Networks ePMP 1000 User Manual

Cambium Networks ePMP 1000
478 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #301 background imageLoading...
Page #301 background image
CAMBIUM NETWORKS
026v003
301
Resetting ePMP to factory defaults by power cycling
Operators may reset an ePMP radio to default factory configuration by a sequence of power
cycling (removing and re-applying power to the device). This procedure allows operators to
perform a factory default reset without a tower climb or additional tools. The procedure is depicted
in Figure 85.
Procedure:
1
Remove the Ethernet cable from PoE jack of the power supply for at least 10 seconds.
2
Reconnect the Ethernet cable to re-supply power to the ePMP device for 3-5 seconds and
disconnect cable to power off the ePMP device for 3-5 seconds. (1
st
power cycle)
3
Reconnect the Ethernet cable to re-supply power to the ePMP device for 3-5 seconds and
disconnect cable to power off the ePMP device for 3-5 seconds. (2
nd
power cycle)
4
Reconnect the Ethernet cable to re-supply power to the ePMP device for 3-5 seconds and
disconnect cable to power off the ePMP device for 3-5 seconds. (3
rd
power cycle)
5
Reconnect the Ethernet cable to re-supply power to the ePMP device for 3-5 seconds and
disconnect cable to power off the ePMP device for 3-5 seconds. (4
th
power cycle)
6
Reconnect the Ethernet cable to re-supply power to the ePMP device for at least 30 seconds
and allow it to go through the boot up procedure (Note: Device will go through an additional
reset automatically). This will reset the current configuration files to factory default
configuration (e.g. IP addresses, Device mode, RF configuration etc.). The device can be
pinged from a PC to check if boot up is complete (Successful ping replies indicates boot up is
complete).
7
Access the ePMP device using the default IP address of 192.168.0.1 (AP) or 192.168.0.2 (SM).
Figure 85 Power cycle timings
Where:
Is:
V+(ON)
Power through PoE has been applied to the device
Off
Power through PoE has been removed from the device
t
on
Time duration for which the device has been powered
on. This should be 3-5 seconds.
t
off
Time duration for which the device has been powered
off. This should be 3-5 seconds.

Table of Contents

Other manuals for Cambium Networks ePMP 1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cambium Networks ePMP 1000 and is the answer not in the manual?

Cambium Networks ePMP 1000 Specifications

General IconGeneral
BrandCambium Networks
ModelePMP 1000
CategoryWireless Access Point
LanguageEnglish

Related product manuals