EPMP 1000 CONNECTORIZED RADIO WITH SYNC HEATER
At startup, if the ePMP connectorized module temperature is at or below 32° F (0° C), an internal
heater is activated to ensure that the device is able to successfully begin operation. The unit’s
heater is only activated when the unit is powered on and will not apply heat to the device once
startup is complete. When the unit temperature is greater than 32° F (0° C), the heater is
deactivated and the unit continues its startup sequence.
The effect on device startup time at various temperatures is defined in Table 16.
Table 16 ePMP 1000 Connectorized Radio with Sync startup times based on ambient temperature
Startup time (from power on to operational)
EPMP 1000 CONNECTORIZED RADIO WITH SYNC AND EXTERNAL ANTENNA
LOCATION
Find a location for the device and external antenna that meets the following requirements:
The equipment is high enough to achieve the best radio path.
People can be kept a safe distance away from the equipment when it is radiating. The safe
separation distances are defined in Calculated distances and power compliance margins on
page 431.
The equipment is lower than the top of the supporting structure (tower, mast or building) or its
lightning air terminal.
The location is not subject to excessive wind loading. For more information, see ePMP 1000
Connectorized Radio with Sync wind loading on page 52.