CHAPTER 6: LEGAL AND REFERENCE
INFORMATION
COMPLIANCE WITH SAFETY STANDARDS
PAGE 6-82
Table 75 Force 300-16 Power compliance margins, 5.1 GHz, ISEDC
Conn
Type
Channel
Bandwidth
Antenna
P
(W)
G
S
(W/m
2
)
d
(m)
R
(m)
S @ 20
cm
(W/m
2
)
PTP
SM
20 MHz
Patch Array, 16
dBi
0.021
40
9.01
0.09
0.1
1.69
PTP
SM
80 MHz
Patch Array, 16
dBi
0.013
40
9.01
0.07
0.1
1.02
PTP
SM
20 MHz
On-board, 2 dBi
0.678
2
9.01
0.10
0.3
2.14
PTP
SM
80 MHz
On-board, 2 dBi
0.089
2
9.01
0.04
0.1
0.28
Table 76 Force 300-16 Power compliance margins, 5.8 GHz, ISEDC
Conn
Type
Channel
Bandwidth
Antenna
P
(W)
G
S
(W/m
2
)
d
(m)
R
(m)
S @ 20 cm
(W/m
2
)
PTP
SM
20 MHz
Patch Array, 16 dBi
0.1
40
9.69
0.18
0.3
7.92
PTP
SM
80 MHz
Patch Array, 16 dBi
0.1
40
9.69
0.18
0.3
7.92
PTP
SM
20 MHz
On-board, 2 dBi
0.830
2
9.69
0.10
0.2
2.62
PTP
SM
80 MHz
On-board, 2 dBi
0.389
2
9.69
0.07
0.1
1.23
Note Gain of antenna in dBi = 10*log (G).
The regulations require that the power used for the calculations is the maximum power
in the transmit burst subject to allowance for source-based time-averaging.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cambium Networks ePMP 3000 Series and is the answer not in the manual?

Cambium Networks ePMP 3000 Series Specifications

General IconGeneral
BrandCambium Networks
ModelePMP 3000 Series
CategoryWireless Access Point
LanguageEnglish

Related product manuals