CHAPTER 2: SYSTEM HARDWARE
PAGE 2-15
Force 300-25 specifications
The Force 300-25 integrated module conforms to the specifications listed in Table 15 and Table 16.
The integrated module meets the low level static discharge specifications identified in Electromagnetic
compatibility (EMC) compliance on page 6-71 and provides internal surge suppression but does not
provide lightning suppression.
Table 15 Force 300-25 physical specifications
Dimensions (Diameter x Depth)
47 cm x 31 cm (18.5 in x 12.2 in)
Table 16 Force 300-25 environmental specifications
-30°C (-22°F) to +55°C (131°F)
124 mph (200 kph) maximum. See Force 300-25 wind loading
on page 2-16 for a full description.
Force 300-25 heater
At startup, if the Force 300-25 module temperature is at or below 32° F (0° C), an internal heater is
activated when the unit is powered on and will not apply heat to the device once startup is complete.
When the unit temperature is greater than 32° F (0° C), the heater is deactivated and the unit continues
its startup sequence.
The effect on device startup time at various temperatures is defined in Table 17.
Table 17 Force 300-25 startup times based on ambient temperature
Startup time (from power on to operational)