EasyManuals Logo

CAME BX243C User Manual

CAME BX243C
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #19 background imageLoading...
Page #19 background image
18
POWER WIRING
1
Connect 120 Vac to L-N terminals on the electronic card, 50/60Hz frequency
maximum.
The electronic card is equipped with an amperometric sensor which constantly
monitors the motor’s drive. If the gate encounters an obstacle, the sensor
immediately detects the overload on the operator and the gate reverses.
Do not apply AC power until instructed.
MN
L2T
L1T
0
17
26
10 11 E1 1 2 3P 5 7 2 C1 C3 C7 C8
TS
+E
FC FA
F
LINE FUSE
230V=1 6A F
120V=3 15A F
C BOARD
FUSE
1A F
ZN5U
ZN5
CONTROL BOARD
1
MN
L2T
L1T
LN
0
17
26
10 11 E1 1 2 3P 5 7 2 C1 C3 C7 C8
TS
+E
FC FA
F
120 Vac Power, 50/60Hz Frequency
WIRE THE ENTRAPMENT PROTECTION
DEVICES
An entrapment protection device such as photoelectric sensors or an edge MUST be
wired to the operator and then configured for your application. NOTE: If entrapment
protection devices are not used, you must jumper the connections to disable the
contacts.
PHOTOELECTRIC SENSOR CONFIGURATIONS
“OPENING DURING CLOSING” (N.C.) CONTACT
If contact is opened while the gate is closing, the gate reverses direction. To select this
function set the number 9 functionality switch to OFF (refer to the "Functionality
Switches" chart on page 22). Default is OFF. To disable this function set the number
9 functionality switch to ON.
“PARTIAL STOP” (N.C.) CONTACT
Gate stops if moving and automatically shuts (if this function has been selected). To
select this function set the number 10 functionality switch to OFF (refer to the
"Functionality Switches" chart on page 22). Default is OFF. To disable this function
set the number 10 functionality switch to ON.
“CLOSE WHILE OPENING” (N.C.) Contact
This input functions to reverse the gate to the close limit when the photoelectric
sensor is activated during the opening cycle.
NOTE: If not used, short circuit contact 2-C8.
POWER WIRING + WIRE THE ENTRAPMENT PROTECTION DEVICES
WIRING
  % 0 # # # #
43
RX
TX
DIR10 Photoelectric Sensors: Partial Stop
  % 0 # # # #
43
RX
TX
DIR10 Photoelectric Sensors: Opening During Closing
  % 0 # # # #
43
RX
TX
DIR10 Photoelectric Sensors: Close While Opening

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CAME BX243C and is the answer not in the manual?

CAME BX243C Specifications

General IconGeneral
BrandCAME
ModelBX243C
CategoryGate Opener
LanguageEnglish

Related product manuals