Page 25 - Manual FA01358-EN - 07/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
F30
Slow-down
speed
Setting the door's opening and closing slow-down speed, calculated as a
percentage.
20 = Minimum speed / 40 = 40% of the motor's speed (default) / 60 =
Maximum speed
F33
Calibration
speed
Setting the gear motor's calibration speed, calculated as a percentage.
30 = 30% of the maximum speed /… /50 = 50% of the maximum speed
(default) /… / 60= 60% of the maximum speed
F34
Travel
sensitivity
Adjusting obstruction detection sensitivity during door travel.
10 = Maximum sensitivity /… / 100= Minimum sensitivity (default)
F35
Slow-down
sensitivity
Adjusting obstruction detection sensitivity during slow-down.
10 = Maximum sensitivity /… / 100= Minimum sensitivity (default)
F36
Adjusting the
partial opening
Adjusting, as a percentage of total door travel, the door's partial opening.
10 = 10% of the door travel /… / 40 = 40% of the door travel (default) /…
/ 80= 80% of the door travel
F41
Adjusting the
opening slow-
down
Percentage adjustment of the total door travel, of the opening slow-down
starting point.
1 = 1% of the door travel / … / 5 = 5% of the door travel (default) / … / 60
= 60% of the door travel
F42
Adjusting the
closing slow-
down
Percentage adjustment of the total door travel, from the closing slow-down
starting point.
1 = 1% of the door travel / … / 15 = 15% of the door travel (default) / … /
60 = 60% of the door travel
F44
Adjusting
the closing
approach
Adjusting, as a percentage of the total door travel, of the closing approach
starting point.
1 = 1% of the door travel / … / 10 = 10% of the door travel (default)
F47
Slowed-down
start when
closing
Adjusting, as a percentage of the total door travel, of the starting of the closing
slow-down.
OFF = Deactivated / 1 = 1% of the door travel (minimum) / … / 5 = 5% of the
door travel
(default) / … / 50 = 50% of the door travel (maximum)
F49
Managing
the serial
connection
For enabling the CRP (Came Remote Protocol).
0 = Deactivated / 3 = CRP (default)
F50 Saving data
Saving users and settings saved in the Memory Roll.
This function only appears if a Memory Roll has been plugged into the
control board.
0 = Deactivated (default) / 1 = Activated
F51 Uploading date
Uploading data saved in the Memory Roll.
This function only appears if a Memory Roll has been plugged into the
control board.
0 = Deactivated (default) / 1 = Activated
Page 25 - Manual FA01358-EN - 07/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Original instructions