Abnormal Recycle: Safety relay drive test failed
Abnormal Recycle: Demand off during Pilot Flame Establishing Period
Abnormal Recycle: LCI off during Drive to Purge Rate
Abnormal Recycle: LCI off during Measured Purge Time
Abnormal Recycle: LCI off during Drive to Lightoff Rate
Abnormal Recycle: LCI off during Pre-Ignition test
Abnormal Recycle: LCI off during Pre-Ignition time
Abnormal Recycle: LCI off during Main Flame Establishing Period
Abnormal Recycle: LCI off during Ignition period
Abnormal Recycle: Demand off during Drive to Purge Rate
Abnormal Recycle: Demand off during Measured Purge Time
Abnormal Recycle: Demand off during Drive to Lightoff Rate
Abnormal Recycle: Demand off during Pre-Ignition test
Abnormal Recycle: Demand off during Pre-Ignition time
Abnormal Recycle: Flame was on during Safe Start check
Abnormal Recycle: Flame was on during Drive to Purge Rate
Abnormal Recycle: Flame was on during Measured Purge Time
Abnormal Recycle: Flame was on during Drive to Lightoff Rate
Abnormal Recycle: Flame was not on at end of Ignition period
Abnormal Recycle: Flame was lost during Main Flame Establishing Period
Abnormal Recycle: Flame was lost early in Run
Abnormal Recycle: Flame was lost during Run
Abnormal Recycle: Leakage test failed
Abnormal Recycle: Interrupted air flow switch was off during Drive to Purge
Abnormal Recycle: Interrupted air flow switch was off during Measured Purge
Abnormal Recycle: Interrupted air flow switch was off during Drive to Lightoff
Abnormal Recycle: Interrupted air flow switch was off during Pre-Ignition test
Abnormal Recycle: Interrupted air flow switch was off during Pre-Ignition time
Abnormal Recycle: Interrupted air flow switch was off during Main Flame
Abnormal Recycle: Ignition failed due to interrupted air flow switch was off
Abnormal Recycle: ILK off during Drive to Purge Rate
Abnormal Recycle: ILK off during Measured Purge Time
Abnormal Recycle: ILK off during Drive to Lightoff Rate
Abnormal Recycle: ILK off during Pre-Ignition test
Abnormal Recycle: ILK off during Pre-Ignition time
Abnormal Recycle: ILK off during Main Flame Establishing Period
Abnormal Recycle: ILK off during Ignition period
Run was terminated due to ILK was off
Run was terminated due to interrupted air flow switch was off
Run was terminated due to fan failure
Abnormal Recycle: Fan failed during Drive to Purge Rate
Abnormal Recycle: Fan failed during Measured Purge Time
Abnormal Recycle: Fan failed during Drive to Lightoff Rate
Abnormal Recycle: Fan failed during Pre-Ignition test
Abnormal Recycle: Fan failed during Pre-Ignition time
Abnormal Recycle: Fan failed during Ignition period
Abnormal Recycle: Fan failed during Main Flame Establishing Period
Abnormal Recycle: Main Valve off after 10 seconds of RUN
Abnormal Recycle: Pilot Valve off after 10 seconds of RUN
Abnormal Recycle: Safety Relay off after 10 seconds of RUN
Abnormal Recycle: Hardware flame bias
Abnormal Recycle: Hardware static flame
Abnormal Recycle: Hardware flame current invalid