Chapter 5
5-1
5.1 Periodic Replacement Parts
5.1.1 Periodic Replacement Parts
0012-6595
5.2 Consumable Parts
5.2.1 Consumable Parts
0032-0598
*1: The counter name is the name of "SERVICE MODE > COUNTER > PARTS CNT. > COUNTER XX-X".
*2: The exchange timing varies by the print mode and operating condition and others. (Print condition: coated paper/ print mode of photo and illustration/
each color 12.5% duty X 4(total 50% duty))
Level Periodic Replacement Part
User None
Service Personnel None
Count
er
name
*1
Name
Parts
number
Q't
y
Life
sheets/
A0 *2
Warning level thresholds Panel message *3
Count
contents
Reference page of
"Points to Note on
Disassembly and
Reassembly"
Level1 Level2 Unit Level1 Level2
CR1 CARRIAGE UNIT QM4-2880 1 28000 11228571 12476190 (X210)
mm
W: Level1 W: Level2 Carriage scan
distances
"Carriage Unit" >
"Removing the
Carriage Unit"
CR2 FLEXIBLE CABLE
UNIT
QM3-4614 1 54000 6030000 6700000 times W: Level1 W: Level2 Carriage scan
times
CR3 CARRIAGE UNIT QM4-2880 1 28000 14850000 16500000 (X1,000,
000) dots
W: Level1 W: Level2 Total ink
discharge
quantity
SCALE, LINEAR QC4-9427 1 "Linear Encoder" >
"Removing the Linear
Encoder"
CR4 CARRIAGE UNIT QM4-2880 1 28000 54000 60000 times W: Level1 W: Level2 Number of
carriage
height
changing cam
rotation
Carriage Unit >
"Removing the
Carriage Unit"
CR5 MULTI SENSOR
UNIT
QM4-3668 1 30000 14850000 16500000 (X1,000,
000) dots
W: Level1 W: Level2 Total ink
discharge
quantity
"Multi Sensor" >
"Removing the Multi
Sensor"
SP1 INK TUBE UNIT QM4-2865 1 35000 3960000 4400000 times W: Level1 E144-4047 Carriage scan
times
"Ink Tube Unit" >
"Removing the Ink
Tube Unit"
PG1 PURGE UNIT QM4-3670 1 50000 45000 50000 times W: Level1 E141-4046 Number of
suction pump
rotation
"Purge Unit" >
"Removing the Purge
Unit"
JOINT, TUBE,
COLOR
QC4-8861 1 "Purge Unit" >
"Removing the Waste
Ink Tube Joint (CL)"
Hma1 HEAD
MANAGEMENT
SENSOR UNIT
QM4-2767 1 100000 30.35 31.29 ml W: Level1 E194-404A Ink discharge
quantity to
head
management
sensor
"Head Management
Sensor" > "Removing
the Head Management
Sensor"
MT1 MOTOR, DC QK1-5068 1 480000 13500 15000 hours - *4 - *4 Carriage scan
hours
"Drive Unit" >
"Removing the
Carriage Motor"
PL1 MOTOR, DC QK1-0447 1 45000 700.20 778 hours - *4 - *4 Media feed
hours
"Drive Unit" >
"Removing the Feed
Motor"
Mi1 FAN UNIT QM4-2798 1 31000 34.97 38.85 ml W: Level1 E146-4001 Mist
collection
quantity
"Waste Ink Collection
Unit" > "Removing the
Mist Fan"
MIST FAN DUCT
UNIT
QM4-2797 1 "Waste Ink Collection
Unit" > "Removing the
Mist Exhaust Duct"
CT1 CUTTER QM4-2881 1 100000 90000 100000 times W: Level1 W: Level2 Cut times (cut
operation to
the forward
direction)
"Cutter" > "Removing
the Cutter"
WF1 M/C HOLDER
UNIT
QM4-2785 1 - (when
the error
occuring
)
254.21 282.45 ml W: Level1 E146-4001 Waste ink
quantity by
suction
operation that
has been
executed
during
detachment of
the
maintenance
cartridge
"Purge Unit" >
"Removing the Waste
Ink Tube Joint (CL)"
WF2 WASTE INK BOX
UNIT
QM4-2753 1 77000 42.53 47.25 ml W: Level1 E146-4001 Mist
collection
quantity by
platen fan
"Waste Ink Collection
Unit" > "Removing the
Platen Exhaust Duct"