1. EMG1/2 bottom pressed.
2. Cover does not close.
3. Inadequate air pressure.
4. Glue pot does not reach operating
temperature.
1. Release EMG bottom and reset machine.
2. Close machine cover.
3. Ensure air pressure is above 7kg/cm
2
(100PSI)
4. Ensure PV reach SV temperature.
Motor stall or
underpowered
1. Motor overheated.
2. Motor overloaded.
3. Plug at fault.
4. Motor bearings at fault.
1. Allow motor to cool. Reset overload if
necessary.
2. Wood chips stuck between blades (remove
wood chips), wire damaged (if necessary, replace
it).
3. Test for good contacts/correct wiring.
4. Test by rotating shaft; rotational grinding/loose
shaft requires bearing replacement.
1. Conveyor belt slipping at fault.
2. Wood chips stuck on belt.
3. Conveyor function flash on touch screen.
1. Tension belt; replace if faulty.
2. Remove wood chips and clean belt.
3. Press conveyor function till 1 loop run finished.
Workpiece feeds
erratically or
stops feeding
during operation
1. Conveyor belt not properly tensioned.
2. Panel feeder height nor properly adjusted.
1. Tension conveyor belt.
2. Adjust panel feeder height.
1. Present temperature does not reach to set
temperature.
2. Standby mode trigger.
1. Wait temperature reach to working
temperature.
2. Disable standby mode on the screen.
1. Temperature sensor broken.
2. Plug at fault.
3. Cannot heat up.
1. Replace sensor.
2. Test for good contacts/ correct wiring.
3. Heater or thermal controller damaged.
Glue spindle does
not rotate
1. Motor does not run.
2. Too much grease added to glue spindle.
3. Gear connection shaft stripped/broken.
1.Breaker trigger(QM2), refer to 6.12.2.
2. Loosen pressure-relief set screw.
3. Inspect/replace gear connection shaft.