8200-M585-O1 Rev D 210 Installation & Technical 57
SETUP AND CALIBRATION, CONT.
Weight On Demand
If continuous output has not been selected for Serial Port 0 (Cont0=NO), the 210 indicator will
respond to a weight request (ENQ).
The host device (computer) sends:
ENQ - (hex 05)
The 210 will respond:
<s><xxxxxx><d><uu><m><cc><cr>
Where:
s = Sign "-" = negative, " " (blank) = positive
xxxxxx.xxx = Weight Six digits
d = Decimal point Added to string if enabled in setup
uu = Units tn, lb, l/o, oz, t, kg, g
m = Mode G = Gross, N = Net
cc = Weight Status OC = overcap
CZ = center of zero
MO = motion
ee = weight not currently being displayed
cr = Carriage Return (hex 0D)
Sio 1? (Setup Serial Port 1)
Press the ENTER key. The display will change to show the current setting no. To skip
configuring the Sio Port 1 (serial input/output) and proceed to the Sio 2? menu, press
the ENTER key again. To configure the Sio 1, press the numeric key 1/YES (display will
change to YES) and then press the ENTER key.
bAUd1= (Serial Port 1 Baud Rate)
Press the ENTER key to show the current value. If the setting displayed is acceptable, press
the ENTER key again to save it. Otherwise, use the numeric keys to enter a new baud rate for
the serial ports, then press the ENTER key to save it. Allowable values are:
12 = 1200 Baud 24 = 2400 Baud 48 = 4800 Baud
96 = 9600 Baud 14 = 14.4k Baud 19 = 19.2k Baud
28 = 28.8k Baud 38 = 38.4k Baud 57 = 57.6k Baud
76 = 76.8k Baud 11 = 115.2k Baud 23 = 230.4k Baud
Prty1= (Serial Port 1 Parity)
Press the ENTER key to show the current value. If the setting displayed is acceptable, press
the ENTER key again to save it. Otherwise, using the numeric keys enter the new setting,
then press the ENTER key to save it. Allowable values are: 0, 1, or 2.
0 = NONE (No Parity) 1 = Odd Parity 2 = Even Parity
bitS1= (Serial Port 1 Data Bits)
Press the ENTER key to show the current value. If the setting displayed is acceptable, press
the ENTER key again to save it. Otherwise, using the numeric keys enter the new setting,
then press the ENTER key to save it. Allowable values are: 7 or 8.
StoP1= (Serial Port 1 Stop Bits)
Press the ENTER key to show the current value. If the setting displayed is acceptable, press
the ENTER key again to save it. Otherwise, using the numeric keys enter the new setting,